Cornell Greenhouse Gas Inventory

Cornell Greenhouse Gas Inventory

Cornell has set a goal to achieve carbon neutrality by 2035.  The annual greenhouse gas (GHG) inventory tracks campus progress towards this goal and shows trends in emissions reduction over time. Upstream methane emissions (UME) are not incorporated in the baseline metric below. For UME data and more information, please see our additional inventory, upstream fuel activities tab.

Progress to Carbon Neutrality

The baseline greenhouse gas inventory measures the categories of emissions from the Ithaca, NY campus included in our commitment to reach carbon neutrality by 2035.  Emissions from all six greenhouse gases are measured and translated into metric tons of carbon dioxide equivalent, and reported using the Second Nature and GHG Protocol methodology. Cornell tracks additional categories of more indirect scope 3 emissions as well to help inform mitigation potential. Use the tabs below to explore our inventory data.

2022 Baseline Inventory

The most recent GHG inventory for FY22 shows net emissions at 159,966 MTCO2e with emissions reduced by about 50% reduction from the 2008 baseline. FY2022 represents reflects a return to more typical operations after the disruption from COVID-19.

COVID-19 Influence on GHG Emissions

FY2020 and FY2021 show a reduction in emissions of over 50% from the 2008 baseline data represents disrupted operations during the COVID-19 pandemic including reduced campus density, and reduced faculty & staff commuting and business air travel. As operations normalized from disruption post-pandemic in FY2022, GHG emissions have risen to reflect a return to on-campus teaching and operations as well as more typical air travel.

Scope 1 Emissions

Scope 1 emissions are direct greenhouse (GHG) emissions that occur from sources that are controlled or owned by an organization (e.g., emissions associated with fuel combustion in boilers, furnaces, vehicles, or during research processes).

Stationary Combustion

Cornell produces its own power, heat, and cooling, overseen by the Energy & Sustainability Department. Cornell moved "Beyond Coal" to natural gas in 2018 as part of a short-term carbon neutrality effort on the road to full renewable energy. Today, the University produces it's own heat and power using a highly efficient natural-gas-fired District Energy and Combined Heat & Power Plant . CHP is expected to be phased out and replaced with renewable energy development such as hydropower and solar and Earth Source Heat by 2035.

Fossil fuel emissions from cooling are also avoided through the use a renewable energy cooling system: Lake Source Cooling (LSC). LSC saves over 20 million kWh per year over traditional cooling methods, leading to an 85% reduction in energy use for campus cooling since the plant began operation in 2000. LSC reduces or eliminates the need for individual-building cooling & air conditioning equipment on campus, greatly reducing CFCs. (Thus, LSC reduces emissions from Stationary Combustion and Refrigerants).

Fleet Vehicles

All vehicles owned or leased by Cornell that burn fuels producing greenhouse gases fall into Scope 1. This includes cars, vans, trucks, tractors, farm equipment, and motorcycles powered by petrol or diesel engines. Most University-owned vehicles are still powered by fossil fuels.

Refrigerants & Chemicals

An important category of Scope 1 direct greenhouse gas (GHG) are fugitive emissions, which result from the direct release to the atmosphere of GHG compounds from various types of equipment and research. Hydrofluorocarbons (HFCs), perfluorocarbons (PFCs) and Sulfur Hexafluoride (SF6) are all used for refrigeration and research at Cornell.

Though small in amount consumed, these gases have 100-year global warming potentials (GWPs), which are typically greater than 1,000 times that of CO2 , so their potential impact on climate change can be significant. By the same token, any reductions of these gases can have a large climate-impact benefit.

Scope 2 Emissions

Scope 2 indirect GHG emissions result from the purchase of electricity, steam, heat, or cooling. Cornell has significantly reduced emissions in this area over time as purchases of heat, steam, cooling, and electricity have waned. In the future, emissions purchased in New York State may have a reduced fossil fuel impact as the state moves to reach renewable energy development goals .

Scope 3 Emissions

What is the impact of other upstream and downstream emissions? View the Additional Greenhouse Gas Inventory page to see waste, food, purchasing, upstream fuel impacts, and other areas of new and emerging analysis on Cornell's greenhouse gas footprint.

GHG Reporting Methodology

Greenhouse gas inventory infographic thumbnail
Click the image to enlarge a diagram of what is included in Cornell University's Baseline Inventory and emerging additional inventories.
Baseline Inventory

Cornell updates a baseline inventory of all emissions categories covered by the Climate Action Plan annually. It includes all Scope 1 and Scope 2 emissions, and Scope 3 emissions from commuting and business air travel. This baseline allows Cornell to participate in national benchmarking using a peer-reviewed GHG reporting protocol shared by all higher education institutions participating in a carbon neutrality goal as part of the Second Nature Carbon Commitment .

Additional Inventory for Scope 3

Indirect emissions result from campus activities that influence greenhouse gas emissions elsewhere. These are called "Scope 3" greenhouse gas emissions. With the exception of daily commuting by employees and students, and university-funded air travel (which are included in our baseline inventory), Cornell assesses and tracks these additional emissions separately as additional inventory categories. Any researcher, course, or campus team can complete an inventory of additional Scope 3 areas which allows for a broader view of Cornell's emissions profile. These inventories are updated by faculty, students, or project teams on a variable basis.

About our GHG Inventory Methodology

Use the tabs below to dive into the details of of our GHG inventory methodology.

Boundaries

  • Emissions from all six greenhouse gases are inventoried

  • Emissions are converted to metric tons of CO2 equivalent (MTCO2e)

  • The University uses the operational control approach to identify campus boundaries; leased assets are not included

  • Ithaca, NY campus only

  • The baseline year for measuring progress is FY2008

Data Collection

Cornell completes the annual inventory using SIMAP® , which relies on the GHG accounting protocol created by the World Resources Institute GHG Protocol which is the world's most widely used greenhouse gas accounting standard.

Baseline Inventory

The baseline inventory includes all Scope 1 and Scope 2 emissions, and select Scope 3 emissions from commuting and business air travel.

Greenhouse gases are divided into scopes based on how directly an organization is responsible for and influences the related activities. Scope 1 are direct emissions, Scope 2 indirect, and Scope 3 are upstream and downstream emissions for which an organization has some control, but also shares decision making or impact with other organizations, or individual choice.

These categories are used by all institutions with a public carbon neutrality commitment participating in the Second Nature Carbon Commitment . Use of this standardized methodology allows our campus to benchmark with other institutions, and keep a consistent baseline and categories to measure progress.

Categories Measured

  • Scope 1
  • Stationary Combustion or University Facilities: Power produced and used on campus, by campus. Includes combustion from the Combined Heat & Power Plant and other energy sources and the use of this energy by our administrative, residential, athletic, research, operational, and other buildings and resources.

  • Fleet Vehicles: Fuel used for university-owned vehicles, such as cars and tractors

  • Refrigerants and Chemicals: Process gases used for refrigeration and research


  • Scope 2

  • Purchased Electricity: Electricity purchased from the grid


  • Scope 3
  • Commuting: Employee and student commuting to and from campus for daily work and study

  • Business Air Travel: University-sponsored business air travel for conferences, meetings, etc.

  • Reductions: Carbon Sinks
  • Carbon sinks offset our campus footprint and are subtracted from the gross emissions produced each year. Sinks currently included come from retired renewable energy certificates, offsets from composting food waste on campus, and emissions associated with exported electricity.

Additional Inventory

In 2016, Cornell adopted the use of an additional Scope 3 inventory for the measurement of new, emerging, or additional areas of Scope 3 greenhouse gas measurement beyond the original baseline.

View Additional Inventory

The additional GHG inventory allows members of the campus community to contribute to a wider view of Cornell's organizational climate impact, without changing the original "goalposts" of the public carbon commitment. This approach advances emerging greenhouse gas accounting using Cornell as a living laboratory to inform best practices in measurement and methdology.

Additional Inventories Measured
  • Upstream Fuel & Energy (Scope 3)
    Measuring methane leakage and associated emissions the production, extraction, and distribution of natural gas

  • Waste and Wastewater (Scope 3)
    Emissions from the production of clean water, and disposal of wastewater

  • Purchased Goods (Including Food) (Scope 3)
    Preliminary assessment of the full supply chain of purchases across Cornell, including food emissions

  • Forest Carbon Sequestration (Scope 3)
    Reductions from carbon sequestration due to forest management practices